Littelfuse
Same series 1206 fuse, but with a higher 2.5A current rating that poses a high electrical risk without redesign.
Reviewing alternatives for the Littelfuse 046801.5NRHF, a 1.5A 63V slow-blow 1206 fuse. Key considerations for replacements are matching the time-delay characteristic and current rating to ensure proper circuit protection.
Mismatched current or fuse type can lead to circuit damage or fire hazard.
The 1206 package is standardized, making physical replacement straightforward.
Fuses are passive components and do not interact with firmware.
No direct, 1-to-1 replacement has been identified. All candidates require parametric adjustments and engineering validation.
Use a parametric search to find a 1.5A, 63V (or higher), slow-blow fuse in a 1206 package from other manufacturers.
Using a fuse with a higher current rating will compromise circuit safety by not blowing under expected fault conditions.

Littelfuse
Same series 1206 fuse, but with a higher 2.5A current rating that poses a high electrical risk without redesign.
| Feature / factor | 046801.5NRHF | 046802.5NRHF | 12T.30000063AG12S1B02 | Alt 3 | Compatibility / risk |
|---|---|---|---|---|---|
| Package | 1206 | 1206 | 1206 | 1206 — Same package size ensures physical compatibility.; 12T.30000063AG12S1B02: Same package size ensures physical compatibility. | |
| Voltage | 63V | 63V | 63V | 63V — Voltage rating is identical.; 12T.30000063AG12S1B02: Voltage rating is identical. | |
| Current | 1.5A | 2.5A | 3.0A | 2.5A / 3.0A — Higher current rating will not protect the circuit at the original level.; 12T.30000063AG12S1B02: Higher current rating will not protect the circuit at the original level. | |
| Polarity Or Type | Slo-Blo® (Time Delay) | Slo-Blo® (Time-Lag) | Slow Blow | Slo-Blo® (Time-Lag) / Slow Blow — Same manufacturer series and time-current characteristic.; 12T.30000063AG12S1B02: Time-current characteristic is comparable (Slow-Blow). | |
| Temperature | -55°C to 90°C | -55°C to 90°C | -55°C to 125°C | -55°C to 90°C / -55°C to 125°C — Operating temperature range is identical.; 12T.30000063AG12S1B02: Wider operating temperature range. |
No direct drop-in replacement was found. Alternatives exist in the same 1206 package, but they have different current ratings (e.g., 2.5A or 3.0A) which requires careful engineering review to ensure circuit safety.