BNstar
A potential alternative with a higher voltage rating but also higher hold and trip currents, requiring engineering review.
BSMD0805-003-30V is a 30V, 30mA hold current PTC resettable fuse in an 0805 package. Finding a suitable replacement requires closely matching the critical hold and trip current ratings to ensure proper circuit protection.
Mismatched hold and trip currents can lead to inadequate circuit protection.
Candidates share the common 0805 package, ensuring physical compatibility.
No direct, drop-in replacement has been identified. All potential candidates have different hold and trip currents, which alters the circuit's protection characteristics and requires engineering validation.
Search for a 0805 PTC fuse with Vmax ≥ 30V, Ih ≈ 30mA, and It ≈ 90mA. The closest identified candidate, SMD0805-004C-60V, requires review for its higher current ratings.
Using a substitute with a higher hold/trip current may result in failure to protect the downstream circuit from overcurrent conditions.

BNstar
A potential alternative with a higher voltage rating but also higher hold and trip currents, requiring engineering review.
| Feature / factor | BSMD0805-003-30V | SMD0805-004C-60V | SMD0805-005C-60V | Alt 3 | Compatibility / risk |
|---|---|---|---|---|---|
| Package | 0805 | 0805 | 0805 | 0805 — Same package and pin count.; SMD0805-005C-60V: Same package and pin count. | |
| Voltage | 30V | 60V | 60V | 60V — Higher voltage rating provides more margin.; SMD0805-005C-60V: Higher voltage rating provides more margin. | |
| Current | 90mA | 120mA | 150mA | 120mA / 150mA — Higher trip current (It).; SMD0805-005C-60V: Significantly higher trip current (It). | |
| Resistance | 6Ω / 50Ω | 5.0Ω / 40.0Ω | 1.5Ω / 20.0Ω | 5.0Ω / 40.0Ω / 1.5Ω / 20.0Ω — Initial/Post-trip resistance values are similar.; SMD0805-005C-60V: Initial/Post-trip resistance values are different. |
BNstar's SMD0805-004C-60V is a potential alternative, but has a higher hold current (40mA vs 30mA) and trip current (120mA vs 90mA). This change in protection level must be verified for your specific application.