Package: 1206BHFUSECircuit ProtectionHold Current: 200 mATrip Current: 460 mAMax Voltage (Vmax): 24 VMax Fault Current (Imax): 40 ATypical Power Dissipation: 0.6 W

BSMD1206-020-24V is a 1206 PTC resettable fuse with a 200mA hold current and 24V rating. Finding a direct replacement requires matching the hold current and trip characteristics closely to maintain circuit protection.

AI replacement insight

Electrical riskhigh

Candidate hold currents are 2.5x or more higher than the target's.

Package risklow

All candidates share the same 1206 package.

Can it be replaced directly?

No direct, low-risk replacement has been identified. All reviewed candidates have a significantly higher hold current, which alters the circuit's protection level.

Best replacement path

Search for 1206 PTC fuses with a hold current near 0.2A and a voltage rating of at least 24V. The current candidates are not suitable direct replacements.

Main risk

Inadequate overcurrent protection due to mismatched hold current, potentially leading to circuit damage.

Recommended alternatives

2
SMD1206-050C-30V package
Needs validationhigh risk

A 1206 PTC fuse with higher voltage (30V) but a much higher hold current (0.5A), requiring careful review.

View details

Alternative comparison matrix

Feature / factorBSMD1206-020-24VSMD1206-050C-30VSMD1206-050C-24VAlt 3Compatibility / risk
Package1206120612061206 — Form factor matches.; SMD1206-050C-24V: Form factor matches.
Voltage24V30V24V30V / 24V — Higher voltage rating provides more margin.; SMD1206-050C-24V: Voltage rating matches but has no safety margin.
Current0.46A1.0A1.0A1.0A — Trip current is over 2x higher.; SMD1206-050C-24V: Trip current is over 2x higher.
Resistance0.35Ω (min)0.15Ω (min)-0.15Ω (min) — Initial and post-trip resistance differ, affecting circuit impedance.