TECHFUSE
Strong alternative with identical key ratings and a higher max fault current for increased robustness.
Find and compare replacements for the BHFUSE BSMD1210-010-30V, a 1210 PTC resettable fuse with a 100mA hold current and 30V rating. We've analyzed several alternatives for form, fit, and function.
Candidates must be checked for max fault current (Imax) and time-to-trip characteristics.
All strong candidates use the same 1210 SMD package.
This is a common PTC fuse type with multiple manufacturers.
Direct replacement for BSMD1210-010-30V should use only Datasheet verified or Strong match candidates; many approved options still require engineering review.
TECHFUSE SMD1210-010 is a strong candidate, matching key electricals with a higher fault current margin. For applications requiring higher voltage tolerance, SMD1210-010-60V is an excellent upgrade.
The primary risk when substituting PTC fuses is a mismatch in max fault current (Imax) and the time-to-trip curve, which can affect circuit protection under fault conditions.

TECHFUSE
Strong alternative with identical key ratings and a higher max fault current for increased robustness.
| Feature / factor | BSMD1210-010-30V | SMD1210-010 | SMD1210-010-60V | SMD1210P010TF | Compatibility / risk |
|---|---|---|---|---|---|
| Package | 1210 | 1210 | 1210 | 1210 | 1210 — Matches form factor.; SMD1210-010-60V: Matches form factor.; SMD1210P010TF: Matches form factor. |
| Voltage | 30.0V | 30.0V | 60.0V | 30.0V | 30.0V / 60.0V — Matches max operating voltage.; SMD1210-010-60V: Higher voltage rating is a safe upgrade.; SMD1210P010TF: Matches max operating voltage. |
| Current | 40A | 100A | 100A | 30A | 100A / 30A — Higher max fault current provides more safety margin.; SMD1210-010-60V: Higher max fault current provides more safety margin.; SMD1210P010TF: Lower max fault current is a potential risk. |
Verified drop-in options for BSMD1210-010-30V are limited in the current batch. Review candidates marked Strong match or Datasheet verified, and validate package, pinout, and electrical limits before committing a BOM change.