Littelfuse
Littelfuse alternative with same package and voltage, but higher hold current.
Find and compare alternatives for the BHFUSE BSMD1812-010-60V, a 60V, 100mA PTC resettable fuse in an 1812 package. Review key parametric differences before selection.
Higher hold current changes the protection threshold.
All candidates match the 1812 package.
No direct drop-in replacement was found. All suitable alternatives have a higher hold current (140mA vs 100mA) which requires design review.
Consider Littelfuse's MINISMDC014F-2 or BHFUSE's BSMD1812-014-60V, but verify the higher 140mA hold current is acceptable for your design.
The primary risk is the increased hold current, which may not provide adequate overcurrent protection for the original design's requirements.

Littelfuse
Littelfuse alternative with same package and voltage, but higher hold current.
| Feature / factor | BSMD1812-010-60V | 1812L014DR | BSMD1812-014-60V | MINISMDC014F-2 | Compatibility / risk |
|---|---|---|---|---|---|
| Package | 1812 | 1812 | 1812 | 1812 | 1812 — Same package and pin count.; BSMD1812-014-60V: Same package and pin count.; MINISMDC014F-2: Same package and pin count.; mSMD014: Same package and pin count. |
| Voltage | 60V | 60V | 60V | 60V | 60V — Voltage rating matches.; BSMD1812-014-60V: Voltage rating matches.; MINISMDC014F-2: Voltage rating matches.; mSMD014: Voltage rating matches. |
| Current | 300mA | 340mA | 340mA | 280mA | 340mA / 280mA — Trip current is slightly higher.; BSMD1812-014-60V: Trip current is slightly higher.; MINISMDC014F-2: Trip current is a close match.; mSMD014: Trip current is slightly higher. |
| Power | 0.8W | 0.8W | - | 0.75W | 0.8W / 0.75W — Power dissipation matches.; MINISMDC014F-2: Power dissipation is slightly lower.; mSMD014: Power dissipation matches. |
| Manufacturer | BHFUSE | - | BHFUSE | - | BHFUSE — Same manufacturer as target. |
Candidates like Littelfuse MINISMDC014F-2 and BHFUSE BSMD1812-014-60V are strong functional matches, but have a higher hold current (140mA vs 100mA). This change must be evaluated for your specific application.