BHFUSE
A form, fit, and functional alternative with the same hold/trip current but a lower max fault current rating.
Finding a substitute for the BHFUSE BSMD1812-400-6V PTC fuse requires matching the 1812 package, 4A hold current, and 8A trip current. Key differences in voltage and max fault current ratings must be reviewed.
Substitutes may have different hold currents or a lower max fault current rating.
Multiple candidates are available in the same 1812 package.
No drop-in replacement is confirmed. BSMD1812-400-12V is the closest functional match but has a lower max fault current (40A vs 100A) which requires engineering review.
BSMD1812-400-12V is the best path, requiring verification of the system's maximum possible fault current against its 40A rating.
The primary risk is using a substitute with a lower maximum fault current rating, which could lead to device failure in a short-circuit event.

BHFUSE
A form, fit, and functional alternative with the same hold/trip current but a lower max fault current rating.
| Feature / factor | BSMD1812-400-6V | BSMD1812-400-12V | SMD1812-500-16V | Alt 3 | Compatibility / risk |
|---|---|---|---|---|---|
| Package | 1812 | 1812 | 1812 | 1812 — Same package ensures form and fit.; SMD1812-500-16V: Same package ensures form and fit. | |
| Current | 100A | 40A | 5.0A | 40A / 5.0A — Max fault current is significantly lower.; SMD1812-500-16V: Higher hold current changes protection level. | |
| Voltage | 6.0V | 12.0V | 16.0V | 12.0V / 16.0V — Higher voltage rating is a safe upgrade.; SMD1812-500-16V: Higher voltage rating is a safe upgrade. | |
| Power | 2.0W | 2.0W | 1.5W | 2.0W / 1.5W — Power dissipation matches.; SMD1812-500-16V: Lower power dissipation may affect trip time. |
The best alternative is BSMD1812-400-12V, which matches the hold current and package. However, its maximum fault current rating is lower (40A vs 100A), which must be verified for your application.