Samsung Electro-Mechanics
A parametric alternative in the same package and dielectric, but with higher capacitance.
Reviewing alternatives for the HRE CGA0805C0G151J500HT, a 150pF 50V 5% C0G 0805 capacitor. Key considerations for substitutes include matching the C0G dielectric and evaluating the impact of different capacitance values.
Capacitance mismatch requires circuit validation.
Candidates share the same 0805 SMD package.
No direct, drop-in replacement was found. All suitable candidates have different capacitance values requiring engineering review.
Find a C0G/NP0 capacitor in an 0805 package with capacitance as close to 150pF as possible. Voltage rating should be 50V or higher.
The main risk is functional failure or performance degradation due to capacitance mismatch. Using a different dielectric like X7R is a critical risk.

Samsung Electro-Mechanics
A parametric alternative in the same package and dielectric, but with higher capacitance.
| Feature / factor | CGA0805C0G151J500HT | CL21C221JBANNNC | TCC0805COG101J500BT | Alt 3 | Compatibility / risk |
|---|---|---|---|---|---|
| Package | 0805 | 0805 (2012 Metric) | 0805 (2012 Metric) | 0805 (2012 Metric) — Package size is compatible.; TCC0805COG101J500BT: Package size is compatible. | |
| Dielectric | C0G | C0G, NP0 | COG (NP0) | C0G, NP0 / COG (NP0) — Matches target's stable C0G dielectric.; TCC0805COG101J500BT: Matches target's stable C0G dielectric. | |
| Capacitance | 150 pF | 220 pF | 100 pF | 220 pF / 100 pF — Higher capacitance (+47%). Requires circuit analysis.; TCC0805COG101J500BT: Lower capacitance (-33%). Requires circuit analysis. | |
| Voltage | 50 V | 50 V | 50 V | 50 V — Voltage rating matches.; TCC0805COG101J500BT: Voltage rating matches. | |
| Tolerance | ±5% | ±5% | ±5% | ±5% — Tolerance matches.; TCC0805COG101J500BT: Tolerance matches. |
The best alternatives are C0G/NP0 capacitors in an 0805 package with a voltage rating of 50V or higher. Candidates like TCC0805COG101J500BT (100pF) or CL21C221JBANNNC (220pF) are options, but the capacitance difference must be acceptable for your application.