Same 2220 package and higher voltage, but different dielectric (X7S) requires review.
The TDK CKG57NX5R1H226MT0S9W is a 22µF 50V stacked MEGACAP capacitor in a 2220 package, designed for high reliability and mechanical strength. Finding a direct replacement is challenging due to its special construction.
Dielectric change from X5R to X7S affects capacitance stability.
Alternatives lack the 'Stacked MEGACAP' construction, impacting mechanical robustness.
Treat substitution as an engineering review, not a simple MPN swap.
Consider TDK C5750X7S2A226MT000N for its matching package and capacitance, but validate the impact of the X7S dielectric and standard MLCC construction on your application.
Mechanical and electrical characteristic mismatch due to the target's unique stacked MEGACAP construction and X5R dielectric.

Same 2220 package and higher voltage, but different dielectric (X7S) requires review.
| Feature / factor | CKG57NX5R1H226MT0S9W | C5750X7S2A226MT000N | FS43X226K500ERG | Alt 3 | Compatibility / risk |
|---|---|---|---|---|---|
| Package | 2220 (5750) | 2220 (5750) | 1812 (4532) | 2220 (5750) / 1812 (4532) — Form and fit compatible.; FS43X226K500ERG: Candidate is smaller, requires layout change. | |
| Dielectric | X5R | X7S | X5R | X7S / X5R — Review capacitance change vs temp and DC bias.; FS43X226K500ERG: matched | |
| Construction | Stacked MEGACAP | Standard MLCC | Standard MLCC | Standard MLCC — Review mechanical stress and vibration performance.; FS43X226K500ERG: Review mechanical stress and vibration performance. | |
| Voltage | 50 V | 100 V | 50 V | 100 V / 50 V — Higher voltage rating provides more margin.; FS43X226K500ERG: matched | |
| Temperature | -55°C to +85°C | -55°C to +125°C | - | -55°C to +125°C — Wider operating range. | |
| Capacitance | 22 µF | - | 22 µF | 22 µF — matched | |
| Tolerance | ±20% | - | ±10% | ±10% — Tighter tolerance is generally acceptable. |
TDK's C5750X7S2A226MT000N is a strong candidate. It matches the 2220 package and 22µF capacitance with a higher 100V rating, but uses an X7S dielectric and is not a stacked MEGACAP. Engineering review is required.