Best Alternatives to DB2ER-5.08-2P-OG

Package: Through HoleNingbo Dorabo Electric Co., Ltd.InterconnectsPitch: 5.08 mmPositions: 2Rated Voltage (UL): 300 VRated Current (UL): 15 AHousing Material: PA66

Find suitable replacements for the DORABO DB2ER-5.08-2P-OG, a 2-position 5.08mm pitch terminal block header. This guide reviews alternatives, comparing electrical ratings, package compatibility, and potential risks.

AI replacement insight

Electrical riskhigh

Several candidates have lower voltage/current ratings. Using them in a 15A circuit is unsafe.

Package risklow

All candidates share the same 2-pos, 5.08mm pitch package, but mechanical drawings must be checked for exact dimensions.

Can it be replaced directly?

No drop-in replacement is verified without comparing datasheet mechanical drawings. However, several candidates offer matching form, fit, and electrical specifications, making them strong potential substitutes.

Best replacement path

DEGSON 2EDGRC-5.08-02P-14-100A(H) and MAX MX2EDGRC-5.08-02P-GN01-Cu-A are strong functional alternatives with matching or better electrical ratings. Verify mechanical drawings before production.

Main risk

The main risk is substituting with a part that has lower voltage or current ratings, which could lead to component failure. Mechanical incompatibility is also a risk.

Recommended alternatives

6

Alternative comparison matrix

Feature / factorDB2ER-5.08-2P-OG2EDGRC-5.08-02P-14-100A(H)MX2EDGRC-5.08-02P-GN01-Cu-AXYEK500-5.08-2PCompatibility / risk
PackageThrough Hole, 2 pos, 5.08mm pitchThrough Hole, 2 pos, 5.08mm pitchThrough Hole, 2 pos, 5.08mm pitchThrough Hole, 2 pos, 5.08mm pitchThrough Hole, 2 pos, 5.08mm pitch — Form factor matches.; MX2EDGRC-5.08-02P-GN01-Cu-A: Form factor matches.; XYEK500-5.08-2P: Form factor matches.; WJ2EDGVM-5.08-02P-14-00A: Form factor matches.
Current15 A (UL)15 A15 A15 A15 A / 10 A (UL) — Current rating matches.; MX2EDGRC-5.08-02P-GN01-Cu-A: Current rating matches.; XYEK500-5.08-2P: Current rating matches.; WJ2EDGVM-5.08-02P-14-00A: Candidate has a lower UL current rating.
Voltage300 V (UL)320 V300 V300 V320 V / 300 V / 300 V (UL) — Higher voltage rating provides more margin.; MX2EDGRC-5.08-02P-GN01-Cu-A: Voltage rating matches.; XYEK500-5.08-2P: Voltage rating matches.; WJ2EDGVM-5.08-02P-14-00A: UL voltage rating matches.
MaterialPA66, UL94V-0PA66PA66 (UL94V-0)PA66PA66 / PA66 (UL94V-0) / PA66, UL94V-0 — Housing material matches.; MX2EDGRC-5.08-02P-GN01-Cu-A: Housing material and flammability match.; XYEK500-5.08-2P: Housing material matches.; WJ2EDGVM-5.08-02P-14-00A: Housing material and flammability match.

Application & sourcing insights

Questions & answers

The best alternatives are 2EDGRC-5.08-02P-14-100A(H) by DEGSON and MX2EDGRC-5.08-02P-GN01-Cu-A by MAX. They match or exceed the 300V/15A rating and share the same package. Always verify mechanical drawings before use.