XINLAIYA
A 5.0mm pitch alternative with a lower current rating (15A) and different wire gauge support.
DB302-5.0-2P-GN-S is a 2-position, 5.0mm pitch PCB terminal block from DORABO. It is notable for its high 20A current rating and ability to accept large 12 AWG wire, making it suitable for power connections.
Most alternatives have a lower current rating, posing a fire or failure hazard if not derated.
PCB footprint and physical dimensions must be verified via datasheet comparison to ensure mechanical fit.
No direct drop-in replacement has been identified. Available alternatives have a lower current rating and require careful design review before use.
Search for 5.0mm pitch terminal blocks with a current rating of 20A or higher and support for 12 AWG wire, then verify the PCB footprint.
The primary risk is electrical overstress due to lower current ratings (15A vs 20A) in common alternatives.

XINLAIYA
A 5.0mm pitch alternative with a lower current rating (15A) and different wire gauge support.
| Feature / factor | DB302-5.0-2P-GN-S | XY2500V-B-5.00-2P | XY301V-A-5.0-2P | Alt 3 | Compatibility / risk |
|---|---|---|---|---|---|
| Pitch | 5.0 mm | 5.0 mm | 5.0 mm | 5.0 mm — Pitch matches.; XY301V-A-5.0-2P: Pitch matches. | |
| Current | 20 A | 15 A | 15 A | 15 A — Significant downgrade from target's 20A rating.; XY301V-A-5.0-2P: Significant downgrade from target's 20A rating. | |
| Voltage | 300 V | 300 V | 300 V | 300 V — Voltage rating matches.; XY301V-A-5.0-2P: Voltage rating matches. | |
| Wire Gauge | 20-12 AWG | 22-14 AWG (from datasheet) | 22-14 AWG | 22-14 AWG (from datasheet) — Does not support thicker 12 AWG wire.; XY301V-A-5.0-2P: Does not support thicker 12 AWG wire. | |
| Package | PCB Terminal Block | Through Hole | Through Hole | Through Hole — Likely compatible, but footprint requires verification.; XY301V-A-5.0-2P: Likely compatible, but footprint requires verification. |
The best alternatives, such as XINLAIYA's XY301V-A-5.0-2P, match the 5.0mm pitch and 300V rating but have a lower current capacity (15A vs 20A). A thorough engineering review is essential before substitution.