AISHI
A likely pin-compatible alternative with identical key ratings and a longer endurance life.
Find suitable replacements for the AISHI EWH1KM221K20OT, a 220µF 100V radial aluminum electrolytic capacitor. This guide provides verified alternatives, from direct pin-compatible options to functional upgrades.
Many alternatives are physically larger or have different lead spacing/styles, requiring PCB redesign.
Capacitance and voltage are standard values. Check secondary parameters like ESR and ripple current for sensitive applications.
Direct replacement for EWH1KM221K20OT should use only Datasheet verified or Strong match candidates; many approved options still require engineering review.
The best replacement is AISHI ERS1KM221K20OT, which matches all key parameters and package dimensions, while offering superior endurance.
The main risk when substituting EWH1KM221K20OT is physical incompatibility. Many functional alternatives have larger packages or different mounting styles.

AISHI
A likely pin-compatible alternative with identical key ratings and a longer endurance life.
| Feature / factor | EWH1KM221K20OT | ERS1KM221K20OT | EWH2DM221M25OT | Alt 3 | Compatibility / risk |
|---|---|---|---|---|---|
| Package | Radial, 13mm x 20mm | Radial, 13mm x 20mm | Radial, 18mm x 25mm | Radial, 13mm x 20mm / Radial, 18mm x 25mm — Package dimensions match.; EWH2DM221M25OT: Physically larger and will not fit the same footprint. | |
| Voltage | 100V | 100V | 200V | 100V / 200V — Voltage rating is identical.; EWH2DM221M25OT: Higher voltage rating is a safe upgrade. | |
| Capacitance | 220µF | 220µF | - | 220µF — Capacitance is identical. | |
| Endurance | 2000h | 10,000h | 2000h | 10,000h / 2000h — Candidate has significantly longer rated life.; EWH2DM221M25OT: Endurance rating is identical. | |
| Pinout | 5mm | - | 7.5mm | 7.5mm — Lead spacing does not match. |
Verified drop-in options for EWH1KM221K20OT are limited in the current batch. Review candidates marked Strong match or Datasheet verified, and validate package, pinout, and electrical limits before committing a BOM change.