Ningbo Songle Relay Co., Ltd.
A potential pin-compatible upgrade with higher current (1A) and a wider voltage range (2.2V-7.5V).
FM116C is a common SOT23-6 H-bridge motor driver for low-voltage applications. Several alternatives exist with similar or improved performance, but careful review of pinout and electrical parameters is required.
Many alternatives offer superior voltage and current ratings.
SOT23-6 is a standard package with high availability.
Most use standard INA/INB control, but some alternatives have different interfaces.
Direct replacement for FM116C should use only Datasheet verified or Strong match candidates; many approved options still require engineering review.
Upgrade to a higher-current driver like BDR6120S or MX113H after verifying pinout from the datasheet.
The main risk is assuming pin-for-pin compatibility without datasheet verification, which could lead to circuit failure.

Ningbo Songle Relay Co., Ltd.
A potential pin-compatible upgrade with higher current (1A) and a wider voltage range (2.2V-7.5V).
| Feature / factor | FM116C | BDR6120S | MX113H | Alt 3 | Compatibility / risk |
|---|---|---|---|---|---|
| Package | SOT23-6 | SOT23-6 | SOT23-6 | SOT23-6 — Package matches.; MX113H: Package matches. | |
| Voltage | 2.5 V to 5 V | 2.2V to 7.5V | 2V to 8V | 2.2V to 7.5V / 2V to 8V — Wider operating voltage range.; MX113H: Wider operating voltage range. | |
| Current | 400mA / 600mA | 1A / 2.5A | 1A / 1.5A | 1A / 2.5A / 1A / 1.5A — Significantly higher continuous and peak current.; MX113H: Higher continuous and peak current. | |
| Temperature | -20 °C to +85 °C | -20°C to 85°C | - | -20°C to 85°C — Operating temperature range matches. | |
| Interface | CMOS Input | PWM (INA-INB) | - | PWM (INA-INB) — Likely compatible, but requires pinout verification. | |
| Standby Current | 0.1 uA | - | <0.1uA | <0.1uA — Standby current matches. |
Verified drop-in options for FM116C are limited in the current batch. Review candidates marked Strong match or Datasheet verified, and validate package, pinout, and electrical limits before committing a BOM change.