BHFUSE
A 1206 PTC fuse with matching hold current and higher voltage, but a much lower max fault current rating.
Finding a substitute for the FTR1206-150 PTC fuse involves matching its 1206 package, 1.5A hold current, and 3A trip current. Key alternatives offer higher voltage ratings but may have different max fault current capabilities.
Lower max fault current (Imax) on all candidates.
All candidates share the same 1206 package.
No direct drop-in replacement is confirmed. While several parts match form and primary function, they have a lower maximum fault current rating that requires engineering validation.
BSMD1206-150-16V or SMD1206-150C-16V, pending fault current analysis.
The replacement part may fail if the circuit's potential fault current exceeds the candidate's lower Imax rating.

BHFUSE
A 1206 PTC fuse with matching hold current and higher voltage, but a much lower max fault current rating.
| Feature / factor | FTR1206-150 | BSMD1206-150-16V | SMD1206-150C-16V | Alt 3 | Compatibility / risk |
|---|---|---|---|---|---|
| Package | 1206 | 1206 | - | 1206 — Same EIA package size. | |
| Voltage | 8V | 16V | - | 16V — Higher voltage rating provides more margin. | |
| Current | 1.5A | 1.5A | - | 1.5A — Hold current matches. | |
| Fault Current | 100A | 40A | - | 50A — Max fault current is lower than target. | |
| Power | 0.8W | 1.0W | - | 0.8W — Power dissipation is identical. |
Candidates like BHFUSE BSMD1206-150-16V and BNstar SMD1206-150C-16V are strong functional matches with the same hold/trip currents and a higher voltage rating. However, their lower max fault current must be reviewed.