cjiang (Changjiang Microelectronics Tech)
Same package and higher current ratings, but lower inductance (6.8µH) requires design validation.
FXL0840-8R2-M is an 8.2µH power inductor from cjiang in an 8.8x8.2mm package. While no direct drop-in replacements have been identified, several functional alternatives from the same series exist that may be suitable after design review.
Candidates have different inductance or lower current ratings.
One candidate has a non-matching, larger package.
No direct, drop-in replacement for FXL0840-8R2-M has been confirmed. All candidates require engineering validation due to parametric or package differences.
For existing PCBs, evaluate FXL0840-6R8-M, but the inductance change is a major risk. For new designs, FXL1040-8R2-M offers matching inductance but requires a larger footprint.
The primary risk is functional failure due to inductance mismatch or physical incompatibility from a different package size.

cjiang (Changjiang Microelectronics Tech)
Same package and higher current ratings, but lower inductance (6.8µH) requires design validation.
| Feature / factor | FXL0840-8R2-M | FXL0840-6R8-M | FXL1040-8R2-M | Alt 3 | Compatibility / risk |
|---|---|---|---|---|---|
| Package | SMD, 8.8x8.2mm | SMD, 8.8x8.2mm | 11.5 mm x 10 mm | SMD, 8.8x8.2mm / 11.5 mm x 10 mm — Package dimensions match.; FXL1040-8R2-M: Larger package requires PCB redesign. | |
| Inductance | 8.2 µH | 6.8 µH | 8.2 µH | 6.8 µH / 8.2 µH — Lower inductance will alter converter performance.; FXL1040-8R2-M: Inductance value matches. | |
| Current | 7.0 A | 8.0 A | 6.8 A | 8.0 A / 6.8 A — Higher rated current (Irms) provides more thermal margin.; FXL1040-8R2-M: Rated current (Irms) is slightly lower than target. | |
| Saturation Current A | 8.7 A | 9.0 A | 9.0 A | 9.0 A — Higher saturation current.; FXL1040-8R2-M: Higher saturation current. | |
| Dcr Ohm | 46 mΩ | 36.8 mΩ | 27 mΩ | 36.8 mΩ / 27 mΩ — Lower DCR improves efficiency.; FXL1040-8R2-M: Lower DCR improves efficiency. |
No direct drop-in replacement is available. FXL0840-6R8-M has the same package but different inductance (6.8µH). FXL1040-8R2-M has the same inductance but a larger package. Both require engineering review.