rubycon
Rubycon alternative with identical electrical ratings but a slightly larger package; requires physical fit verification.
Finding a replacement for the ROQANG GR1A471M0608, a 470µF 10V radial capacitor, involves matching electrical specs and physical size. Several functional alternatives exist, but careful review of dimensions is critical.
Target is 6x8mm; most alternatives are much larger and will not fit.
Capacitance and voltage are common values; many parts match or exceed electrical specs.
Direct replacement for GR1A471M0608 should use only Datasheet verified or Strong match candidates; many approved options still require engineering review.
The Rubycon 10YXJ470M6.3X11 is the strongest candidate, but requires verifying the 3mm height increase is acceptable.
Physical package size mismatch is the primary risk. Most alternatives are significantly larger than the 6x8mm target part.

rubycon
Rubycon alternative with identical electrical ratings but a slightly larger package; requires physical fit verification.
| Feature / factor | GR1A471M0608 | 10YXJ470M6.3X11 | EEUFR1H471 | KF471M025F115A | Compatibility / risk |
|---|---|---|---|---|---|
| Capacitance | 470 µF | 470 µF | 470 µF | 470 µF | 470 µF — Capacitance matches target.; EEUFR1H471: Capacitance matches target.; KF471M025F115A: Capacitance matches target. |
| Voltage | 10 V | 10 V | 50 V | 25 V | 10 V / 50 V / 25 V — Voltage rating matches target.; EEUFR1H471: Higher voltage rating provides more margin.; KF471M025F115A: Higher voltage rating provides more margin. |
| Package | Radial, 6x8mm | Radial, 6.3x11mm | Radial, 10x20mm | Radial, 10x16mm | Radial, 6.3x11mm / Radial, 10x20mm / Radial, 10x16mm — Slightly larger diameter and 3mm taller. Verify clearance.; EEUFR1H471: Significantly larger package. Not a drop-in replacement.; KF471M025F115A: Significantly larger package. Not a drop-in replacement. |
| Tolerance | ±20% | ±20% | - | - | ±20% — Tolerance matches target. |
Verified drop-in options for GR1A471M0608 are limited in the current batch. Review candidates marked Strong match or Datasheet verified, and validate package, pinout, and electrical limits before committing a BOM change.