Murata Electronics
Strong alternative in the same 0805 package with a similar X7R dielectric; engineering review of temperature characteristics is advised.
Find and compare verified substitutes for the Murata GRM21BC71H475KE11L, a 4.7uF 50V 0805 X7S MLCC. Review key parametric differences and sourcing options.
Dielectric change (X7S to X7R/X5R) affects stability and/or temperature range.
Many functional alternates are in larger packages (1206/1210) and are not drop-in compatible.
No verified direct drop-in replacement exists. The closest candidate, GRM21BZ71H475KE15K, requires review of the dielectric change from X7S to X7R.
Evaluate GRM21BZ71H475KE15K for its form-fit compatibility, noting the minor dielectric difference from X7S to X7R.
The primary risk is a change in dielectric material, which impacts the capacitor's performance over temperature and DC bias.

Murata Electronics
Strong alternative in the same 0805 package with a similar X7R dielectric; engineering review of temperature characteristics is advised.
| Feature / factor | GRM21BC71H475KE11L | GRM21BZ71H475KE15K | GRT21BR61H475KE13L | Alt 3 | Compatibility / risk |
|---|---|---|---|---|---|
| Package | 0805 (2012 metric) | 0805 (2012 metric) | 0805 (2012 metric) | 0805 (2012 metric) — Identical package and pin count.; GRT21BR61H475KE13L: Identical package and pin count. | |
| Voltage | 50.0 V | 50.0 V | - | 50.0 V — Voltage rating is identical. | |
| Capacitance | 4.7e-06 F | 4.7e-06 F | - | 4.7e-06 F — Capacitance is identical. | |
| Dielectric | X7S | X7R | X5R | X7R / X5R — X7R offers similar or better temp stability vs X7S. Review required.; GRT21BR61H475KE13L: X5R has a more limited operating temperature range. | |
| Temperature | -55°C to +125°C | - | -55°C to +85°C | -55°C to +85°C — Max temperature is lower than target's +125°C. | |
| Application | General Purpose | - | AEC-Q200 | AEC-Q200 — Candidate is automotive grade. |
GRM21BZ71H475KE15K is a strong alternative in the same 0805 package with similar specs, but uses an X7R dielectric which should be reviewed for your application's temperature stability needs.