BNstar
Matches power dissipation and offers higher voltage, but has a lower max fault current.
JK-MSMD200-24V is a 2A, 24V PTC resettable fuse in an 1812 package. While several alternatives match its form and basic ratings, they often have a lower maximum fault current, requiring careful engineering review before substitution.
Candidate Imax (40A) is much lower than target (100A), risking device failure and fire hazard.
All viable candidates share the same 1812 package and 2-pin layout.
No direct drop-in replacement has been identified. All reviewed candidates have a significantly lower maximum fault current rating (40A vs. 100A), which poses a safety risk.
Select a candidate with matching hold/trip current and package, such as BSMD1812-200-24V, but only if the application's maximum fault current is well below 40A.
The primary risk is the lower maximum fault current (Imax) of candidates, which could lead to fuse failure in a high-current fault event.

BNstar
Matches power dissipation and offers higher voltage, but has a lower max fault current.
| Feature / factor | JK-MSMD200-24V | SMD1812-200C-30V | BSMD1812-200-24V | BSMD1812-200-33V | Compatibility / risk |
|---|---|---|---|---|---|
| Package | 1812 | 1812 | - | - | 1812 — Form and fit are identical. |
| Current | 2.0A | 40A | - | - | 2.0A — Hold current (Ih) matches. |
| Voltage | 24.0V | 30.0V | - | - | 24.0V — Maximum voltage rating matches. |
| Power | 0.8W | 0.8W | - | - | 1.0W — Higher power dissipation may alter trip time. |
The best alternatives for JK-MSMD200-24V are parts like BHFUSE BSMD1812-200-24V, which match hold current, trip current, and package. However, you must verify if your circuit's maximum fault current is below their 40A rating.