Package: Radial LeadedNK TechnologiesCircuit ProtectionHold Current: 180 mATrip Current: 650 mAMax Interrupt Voltage: 250 VMax Fault Current: 10 APower Dissipation: 1.0 W

Finding a substitute for the JK250-180U PTC resettable fuse requires careful matching of hold current, voltage, and trip time. While some parts share the same package and key ratings, differences in trip characteristics pose a risk.

AI replacement insight

Electrical riskhigh

Slower trip time and different resistance require re-validation.

Package risklow

Package is a compatible radial leaded type.

Sourcing riskmedium

Alternative is from a different manufacturer, requiring vendor qualification.

Can it be replaced directly?

No direct drop-in replacement has been identified. The closest candidate, JK250-180T, has a slower trip time which is a critical safety parameter.

Best replacement path

The best path is to evaluate JK250-180T, but only if the application can tolerate a trip time of 3 seconds instead of 1.5 seconds.

Main risk

The primary risk is a slower trip time, which could lead to damage in the protected circuit during an overcurrent event.

Recommended alternatives

1
JK250-180T package
JK250-180T

Jinrui Electronic Materials Co.

Needs validationhigh risk

A functional alternative with the same voltage and hold current, but slower trip time requires engineering review.

View details

Alternative comparison matrix

Feature / factorJK250-180UJK250-180TAlt 2Alt 3Compatibility / risk
PackageRadial LeadedRadial LeadedRadial Leaded — Same package and pin count.
Voltage250V250V250V — Voltage rating matches.
Current180mA180mA180mA — Hold current matches.
Trip Time1.5s3s3s — Slower trip time increases risk to protected circuit.
Resistance2.0-4.0Ω1.0-2.2Ω1.0-2.2Ω — Different initial resistance range may affect circuit behavior.

Application & sourcing insights

Questions & answers

JK250-180T is a potential functional alternative with the same 250V rating and 180mA hold current. However, its trip time is slower (3s vs 1.5s), which requires careful engineering review to ensure circuit safety.