Murata Electronics
Offers higher current (1A) and lower DCR (0.03Ω) in the same 0402 package, with a very close inductance value (1.5nH).
Finding a replacement for the Murata LQG15HS1N6S02D 1.6nH inductor involves matching its 0402 package, RF performance, and current rating. Several options exist with varying trade-offs.
Candidates have different inductance or DCR values that require circuit analysis.
Viable alternatives share the same 0402 package, ensuring physical compatibility.
Direct replacement for LQG15HS1N6S02D should use only Datasheet verified or Strong match candidates; many approved options still require engineering review.
The Murata LQW15AN1N5B00D is the strongest candidate, offering superior current handling and lower resistance in the same package with a very close inductance value.
The primary risk is inductance mismatch, which can detune RF circuits or affect filter performance. Always verify this parameter.

Murata Electronics
Offers higher current (1A) and lower DCR (0.03Ω) in the same 0402 package, with a very close inductance value (1.5nH).
| Feature / factor | LQG15HS1N6S02D | LQW15AN1N5B00D | LQG15HN1N3S02D | Alt 3 | Compatibility / risk |
|---|---|---|---|---|---|
| Package | 0402 (1005 metric) | 0402 (1005 metric) | 0402 (1005 metric) | 0402 (1005 metric) — Same package and pin count.; LQG15HN1N3S02D: Same package and pin count. | |
| Inductance | 1.6 nH | 1.5 nH | 1.3 nH | 1.5 nH / 1.3 nH — Slightly lower but within target's tolerance band.; LQG15HN1N3S02D: Lower inductance, at the edge of target's tolerance. | |
| Current | 0.3 A | 1.0 A | 1.0 A | 1.0 A — Significantly higher current rating.; LQG15HN1N3S02D: Higher current rating. | |
| Dcr | 0.14 Ω | 0.03 Ω | 0.08 Ω | 0.03 Ω / 0.08 Ω — Lower DCR improves efficiency.; LQG15HN1N3S02D: Lower DCR. | |
| Srf | 6 GHz | 18 GHz | - | 18 GHz — Higher self-resonant frequency. |
Verified drop-in options for LQG15HS1N6S02D are limited in the current batch. Review candidates marked Strong match or Datasheet verified, and validate package, pinout, and electrical limits before committing a BOM change.