BNstar
Strong functional match with identical hold current and higher voltage rating, but lacks automotive qualification.
MF-MSMF200-2 is a 2A, 8V PTC resettable fuse in an 1812 package, qualified to AEC-Q200 for automotive use. Finding a substitute requires matching its current ratings and, critically, its automotive-grade qualification.
Candidates lack AEC-Q200 qualification, making them unsuitable for automotive use without extensive testing.
Some candidates have different hold currents, which will alter the circuit's protection characteristics.
No direct, fully-qualified replacement was found. The closest match, SMD1812-200C-16V, lacks the target's AEC-Q200 automotive qualification.
For non-automotive applications, SMD1812-200C-16V is a strong candidate with matching current ratings. For automotive use, a new search for an AEC-Q200 qualified 2A/8V+ PTC fuse is required.
The primary risk is using a non-automotive qualified part in an automotive application, which can lead to reliability issues. A secondary risk is selecting a part with a different current rating, compromising overcurrent protection.

BNstar
Strong functional match with identical hold current and higher voltage rating, but lacks automotive qualification.
| Feature / factor | MF-MSMF200-2 | SMD1812-200C-16V | SMD1812-260C-24V | Alt 3 | Compatibility / risk |
|---|---|---|---|---|---|
| Package | 1812 (4532 metric) | 1812 | 1812 | 1812 — Form factor matches.; SMD1812-260C-24V: Form factor matches. | |
| Current | 2.0A | 2.0A | 2.6A | 2.0A / 2.6A — Hold current matches target.; SMD1812-260C-24V: Higher hold current (+30%) will change the circuit's protection point. | |
| Voltage | 8.0V | 16.0V | 24.0V | 16.0V / 24.0V — Higher voltage rating provides more margin.; SMD1812-260C-24V: Much higher voltage rating provides significant margin. | |
| Resistance | 0.08Ω | 0.120Ω | - | 0.120Ω — Higher max resistance may affect post-trip behavior. | |
| Application | AEC-Q200 | Not specified | Not specified | Not specified — Target is AEC-Q200 qualified for automotive use; candidate is not.; SMD1812-260C-24V: Target is AEC-Q200 qualified; candidate is not. |
The best alternative found is SMD1812-200C-16V, which matches the 2A hold current and 1812 package. However, it is not AEC-Q200 qualified and is only suitable for non-automotive applications.