Best Alternatives to MX128-2.54-03P-GN01-Cu-Y-A

Package: Terminal BlockCybermaxInterconnectsNumber of Positions: 3Pitch: 2.54 mmRated Voltage (UL): 150 VRated Current (UL): 6 AWire Gauge: 24-18 AWG

Find and compare alternatives for the MAX MX128-2.54-03P-GN01-Cu-Y-A, a 3-position 2.54mm pitch terminal block. This page provides analysis of functional and parametric alternatives, highlighting key differences to aid in your selection.

AI replacement insight

Package riskmedium

Footprint and housing dimensions must be verified from datasheets for all candidates.

Electrical riskmedium

Some candidates have lower current ratings or different wire gauge support, requiring application review.

Can it be replaced directly?

No drop-in replacement has been verified. XY308-2.54-3P and DB141V-2.54-3P-GN are strong functional alternatives that require datasheet review to confirm their footprint matches the target part.

Best replacement path

XY308-2.54-3P and DB141V-2.54-3P-GN are the strongest candidates as their key electrical ratings match. However, their mechanical footprint must be verified.

Main risk

The primary risk is mechanical incompatibility. Even with the same pitch, the housing dimensions and pin footprint can vary between manufacturers.

Recommended alternatives

4
DB141V-2.54-3P-GN package
Needs validationmedium risk

Strong functional match with same voltage/current ratings. Footprint verification is required.

View details

Alternative comparison matrix

Feature / factorMX128-2.54-03P-GN01-Cu-Y-ADB141V-2.54-3P-GNXY308-2.54-3PMX2EDGRC-2.54-03P-GN01-Cu-ACompatibility / risk
Current6 A6 A6 A5 A6 A / 5 A — matched; XY308-2.54-3P: matched; MX2EDGRC-2.54-03P-GN01-Cu-A: Candidate current is lower than target.; DB2EK-2.54-3P-GN-S: Candidate current is lower.
Voltage150 V150 V150 V150 V150 V — matched; XY308-2.54-3P: matched; MX2EDGRC-2.54-03P-GN01-Cu-A: matched; DB2EK-2.54-3P-GN-S: matched
Application24-18 AWG26-18 AWG26-18 AWG-26-18 AWG / 26-20 AWG — Wider wire gauge range is generally acceptable.; XY308-2.54-3P: Wider wire gauge range is generally acceptable.; DB2EK-2.54-3P-GN-S: Accepts smaller wires, may not fit target's intended wire.
PackageTerminal BlockPCB MountThrough HoleTerminal BlockPCB Mount / Through Hole / Terminal Block — Package name differs, requires footprint verification.; XY308-2.54-3P: Package name differs, requires footprint verification.; MX2EDGRC-2.54-03P-GN01-Cu-A: Package type matches.; DB2EK-2.54-3P-GN-S: matched
Temperature-40°C to +105°C---40°C to +105°C-40°C to +105°C — matched

Application & sourcing insights

Questions & answers

The best alternatives are XY308-2.54-3P and DB141V-2.54-3P-GN, as their voltage and current ratings match the target. However, you must verify their mechanical drawings to ensure they fit your PCB layout.