FOJAN
A strong match with identical resistance, tolerance, power rating, and 0402 package.
Finding a substitute for the RC-02K3162FT resistor involves matching its 31.6kΩ resistance, ±1% tolerance, and 0402 package. Several alternatives exist, with key differences in resistance value and power rating.
Low for exact matches, Medium for parts with different resistance. The deviation must be within the circuit's tolerance.
Low, as all reviewed candidates use the standard 0402 package.
Direct replacement for RC-02K3162FT should use only Datasheet verified or Strong match candidates; many approved options still require engineering review.
The most direct path is using FRC0402F3162TS, which is a parametric match. For applications that can tolerate a slight resistance change, ERJ2RKF3302X offers a higher power rating.
The main risk is using an alternative with a different resistance value without verifying its impact on the circuit's function.

FOJAN
A strong match with identical resistance, tolerance, power rating, and 0402 package.
| Feature / factor | RC-02K3162FT | FRC0402F3162TS | ERJ2RKF3302X | RC-02K3002FT | Compatibility / risk |
|---|---|---|---|---|---|
| Resistance | 31.6 kΩ | 31.6 kΩ | 33 kΩ | 30 kΩ | 31.6 kΩ / 33 kΩ / 30 kΩ — Exact match.; ERJ2RKF3302X: Resistance is 4.4% higher.; RC-02K3002FT: Resistance is 5.1% lower. |
| Tolerance | ±1% | ±1% | - | ±1% | ±1% — Exact match.; RC-02K3002FT: Exact match. |
| Power | 0.0625 W | 0.0625 W | 0.1 W | 0.0625 W | 0.0625 W / 0.1 W — Exact match.; ERJ2RKF3302X: Higher power rating is an upgrade.; RC-02K3002FT: Exact match. |
| Tcr | ±100 ppm/°C | ±100 ppm/°C | - | - | ±100 ppm/°C — Exact match. |
| Package | 0402 | 0402 | 0402 | 0402 | 0402 — Identical package.; ERJ2RKF3302X: Identical package.; RC-02K3002FT: Identical package. |
| Application | Commercial | - | AEC-Q200 | - | AEC-Q200 — Automotive grade, an upgrade. |
Verified drop-in options for RC-02K3162FT are limited in the current batch. Review candidates marked Strong match or Datasheet verified, and validate package, pinout, and electrical limits before committing a BOM change.