Littelfuse
A functional alternative with the same hold/trip currents and package, but higher initial resistance requires verification.
The RUILON RL60-050 is a 60V, 0.5A hold current PTC resettable fuse in a radial leaded package. Alternatives exist but require careful review of initial resistance and power dissipation.
Higher initial resistance requires verification.
Radial leaded package is a common standard.
No direct drop-in replacement has been identified. The closest candidates, like Littelfuse RXEF050, have a higher initial resistance that requires circuit analysis.
Cross to Littelfuse RXEF050 series.
Increased series resistance from the substitute part may cause unacceptable voltage drop or power loss during normal operation.

Littelfuse
A functional alternative with the same hold/trip currents and package, but higher initial resistance requires verification.
| Feature / factor | RL60-050 | RXEF050 | RXEF050-2 | Alt 3 | Compatibility / risk |
|---|---|---|---|---|---|
| Package | Radial Leaded | Radial Leaded | Radial Leaded | Radial Leaded — Same package type and pin count.; RXEF050-2: Same package type and pin count. | |
| Voltage | 60V | 72V | 72V | 72V — Higher voltage rating provides more margin.; RXEF050-2: Higher voltage rating provides more margin. | |
| Current | 0.5A | 0.5A | 0.5A | 0.5A — Hold current matches target.; RXEF050-2: Hold current matches target. | |
| Resistance | 0.40Ω min | 0.50Ω - 0.77Ω | 0.50Ω - 0.77Ω | 0.50Ω - 0.77Ω — Higher initial resistance may increase voltage drop.; RXEF050-2: Higher initial resistance may increase voltage drop. | |
| Power | 0.8W | - | 1.29W | 1.29W — Higher power dissipation may affect thermal performance. |
The Littelfuse RXEF050 is a strong functional alternative with the same hold/trip currents and a higher voltage rating. However, its initial resistance is higher, which must be evaluated for your specific application.