Best Alternatives to RLP25FEGR001

Package: 2512TAI-TECHSpecialized ResistorsPower Rating: 3 WResistance: 1 mΩTolerance: ±1%Temperature Coefficient: ±50 ppm/℃Package: 2512 (6432)

TAI-TECH RLP25FEGR001 is a 3W, 1mΩ, 2512 current sense resistor with a tight ±50ppm/°C TCR. Finding direct replacements requires careful matching of this temperature coefficient.

AI replacement insight

Electrical riskmedium

TCR degradation from ±50ppm/°C to ±100ppm/°C can affect measurement accuracy in sensitive applications.

Package risklow

The 2512 package is standard, ensuring mechanical compatibility.

Can it be replaced directly?

No direct, drop-in replacement without caveats has been identified. Alternatives exist but have a weaker Temperature Coefficient (TCR), which requires engineering review.

Best replacement path

Source candidates with a TCR of ±50ppm/°C or better. If unavailable, evaluate candidates with ±100ppm/°C, verifying the impact on system performance.

Main risk

TCR mismatch, potentially impacting circuit precision across the operating temperature range.

Recommended alternatives

2
ECSR2512FR001K9 package
Needs validationmedium risk

Matches package, resistance, and power, but has a weaker temperature coefficient (TCR).

View details

Alternative comparison matrix

Feature / factorRLP25FEGR001ECSR2512FR001K9HoLLR2512-3W-1mR-1%Alt 3Compatibility / risk
Package2512251225122512 — Form factor matches.; HoLLR2512-3W-1mR-1%: Form factor matches.
Resistance1mΩ1mΩ1mΩ1mΩ — Resistance matches.; HoLLR2512-3W-1mR-1%: Resistance matches.
Power3W3W3W3W — Power rating matches.; HoLLR2512-3W-1mR-1%: Power rating matches.
Tolerance±1%±1%±1%±1% — Tolerance matches.; HoLLR2512-3W-1mR-1%: Tolerance matches.
Tcr±50 ppm/℃±100 ppm/℃≤100ppm/°C±100 ppm/℃ / ≤100ppm/°C — Worse temperature stability.; HoLLR2512-3W-1mR-1%: Worse temperature stability.

Application & sourcing insights

Questions & answers

Candidates like Milliohm HoLLR2512-3W-1mR-1% and RESI ECSR2512FR001K9 match in package, resistance, and power, but have a higher TCR. They may be suitable if the application can tolerate lower thermal stability.