Littelfuse
Likely a direct replacement from the same manufacturer, differing only in packaging. All key electrical parameters match.
Find datasheet-verified substitutes for the Littelfuse RXEF050-2, a 72V 0.5A radial leaded PTC resettable fuse. Review pin-compatible and functional alternatives, noting differences in performance.
Risk is low if hold/trip currents and voltage are matched.
Radial leaded is a common package, but lead spacing must be verified.
Multiple vendors produce similar parts, but qualification is needed.
Direct replacement for RXEF050-2 should use only Datasheet verified or Strong match candidates; many approved options still require engineering review.
Use the base part RXEF050 for the most direct replacement, or the A72-050 as a strong cross-vendor alternative after datasheet review.
The main risk is selecting a part with an incorrect hold current, which would fail to protect the downstream circuit as intended.

Littelfuse
Likely a direct replacement from the same manufacturer, differing only in packaging. All key electrical parameters match.
| Feature / factor | RXEF050-2 | RXEF050 | A72-050 | Alt 3 | Compatibility / risk |
|---|---|---|---|---|---|
| Code | RXEF050-2 | RXEF050 | - | RXEF050 — Base part number matches, suffix differs. Likely a packaging variant. | |
| Voltage | 72V | 72V | 72V | 72V — Maximum voltage rating is identical.; A72-050: Maximum voltage rating is identical. | |
| Current | 0.5A | 0.5A | 0.5A | 0.5A — Hold current is identical.; A72-050: Hold current is identical. | |
| Trip Current | 1.0A | 1.0A | 1.0A | 1.0A — Trip current is identical.; A72-050: Trip current is identical. | |
| Package | Radial Leaded | Radial Leaded | Radial Leaded | Radial Leaded — Package style is identical.; A72-050: Package style is the same, but dimensions require verification. | |
| Power | 1.29W | - | 0.8W | 0.8W — Power dissipation is within an acceptable range. |
Verified drop-in options for RXEF050-2 are limited in the current batch. Review candidates marked Strong match or Datasheet verified, and validate package, pinout, and electrical limits before committing a BOM change.