SEAWARD
Functional alternative in SOT-89 package, but with a much lower 35V maximum input voltage and reduced temperature range.
SE8633X2-HF is a high-voltage (80V) LDO linear regulator in a SOT-89 package. It provides a fixed 3.3V output at 200mA with an ultra-low quiescent current of 1.8µA, making it ideal for power-sensitive, high-voltage applications.
All candidates have max input voltage <= 35V, versus the target's 80V rating.
While SOT-89 candidates exist, the target's pinout is unverified, requiring manual checks.
These are simple LDOs with no associated firmware, so there is no risk in this area.
Direct replacement for SE8633X2-HF should use only Datasheet verified or Strong match candidates; many approved options still require engineering review.
Downgrade to a lower voltage part like SE8533K1-HF (35V max) if the application's actual input voltage allows.
The primary risk is electrical overstress due to the much lower input voltage rating of all available alternatives.

SEAWARD
Functional alternative in SOT-89 package, but with a much lower 35V maximum input voltage and reduced temperature range.
| Feature / factor | SE8633X2-HF | SE8533K1-HF | HT7333 | Alt 3 | Compatibility / risk |
|---|---|---|---|---|---|
| Package | SOT-89 | SOT-89 | SOT-89 | SOT-89 — Package matches, but pinout is unverified.; HT7333: Package matches, but pinout is unverified. | |
| Voltage | 80V | 35V | 20V | 35V / 20V — Candidate input voltage is significantly lower.; HT7333: Candidate input voltage is critically lower. | |
| Current | 200mA | 200mA | 300mA | 200mA / 300mA — Output current matches.; HT7333: Output current is higher. | |
| Temperature | -40°C to 105°C | -20°C to 85°C | - | -20°C to 85°C — Candidate has a narrower operating temperature range. | |
| Quiescent Current | 1.8µA | 2.5µA | 1.5µA | 2.5µA / 1.5µA — Quiescent current is slightly higher.; HT7333: Quiescent current is an excellent match. |
Verified drop-in options for SE8633X2-HF are limited in the current batch. Review candidates marked Strong match or Datasheet verified, and validate package, pinout, and electrical limits before committing a BOM change.