CEAIYA
A potential upgrade with higher current ratings (4.5A Isat) in the same 6045 package, but review the increased DCR for efficiency impact.
SLF6045T-100M1R6-3PF is a 10µH shielded power inductor in a 6045 package. When seeking replacements, focus on matching the 10µH inductance, 6045 package, and ensuring current ratings (Isat/Irise ≥ 1.6A) and DCR (≤ 39mΩ) meet or exceed original specs for optimal performance.
Most alternatives have higher DCR, impacting efficiency and thermals.
Several candidates match the 6045 package, but others require a redesign.
Multiple vendors offer similar parts in this category.
No perfect drop-in replacement is identified. VLS6045EX-100M-H is a strong candidate in the same package but has slightly higher DCR. CR6045H-100M is also a strong option with higher current ratings but also higher DCR.
VLS6045EX-100M-H offers a significant upgrade in current handling and is AEC-Q200 qualified, with only a minor increase in DCR.
The main risk is increased DC resistance (DCR) in most alternatives, which leads to lower efficiency and more heat. Alternatives with different packages or inductance require board redesign.

CEAIYA
A potential upgrade with higher current ratings (4.5A Isat) in the same 6045 package, but review the increased DCR for efficiency impact.
| Feature / factor | SLF6045T-100M1R6-3PF | CR6045H-100M | CR6045-100M | VLS6045EX-100M-H | Compatibility / risk |
|---|---|---|---|---|---|
| Package | 6045 | 6045 | 6045 | 6045 | 6045 — Package size matches.; CR6045-100M: Package size matches.; VLS6045EX-100M-H: Package size matches. |
| Inductance | 10 µH | 10 µH | 10 µH | 10 µH | 10 µH — Inductance matches.; CR6045-100M: Inductance matches.; VLS6045EX-100M-H: Inductance matches. |
| Saturation Current A | 1.6 A | 4.5 A | 3.0 A | 3.9 A | 4.5 A / 3.0 A / 3.9 A — Significantly higher saturation current.; CR6045-100M: Higher saturation current.; VLS6045EX-100M-H: Significantly higher saturation current. |
| Current A | 1.6 A | 2.7 A | - | - | 2.7 A — Higher thermal current rating. |
| Dcr Ohm | 0.039 Ω | 0.057 Ω | 0.1 Ω | 0.047 Ω | 0.057 Ω / 0.1 Ω / 0.047 Ω — Higher DCR will increase power loss.; CR6045-100M: Significantly higher DCR will cause major power loss.; VLS6045EX-100M-H: Slightly higher DCR may affect efficiency. |
| Application | Commercial | - | - | AEC-Q200 | AEC-Q200 — Automotive grade, an upgrade. |
VLS6045EX-100M-H is a strong upgrade, offering higher current ratings and AEC-Q200 qualification in the same package, though with slightly higher DCR. Always verify performance in your specific application.