Package: 0805TECHFUSECircuit ProtectionOperating Voltage (Max): 33VHold Current: 100mATrip Current: 300mACurrent Rating (Max): 100APower Dissipation: 0.5W

Finding a substitute for the TECHFUSE SMD0805-010-33V PTC fuse requires matching its 33V rating, 0805 package, and 100mA hold current. Alternatives exist but may have different current ratings requiring review.

AI replacement insight

Electrical riskmedium

Hold/trip current mismatch requires circuit analysis.

Package risklow

Candidates share the common 0805 package.

Can it be replaced directly?

No direct drop-in replacement with identical key parameters was found. Available alternatives have a higher hold current, which reduces the level of overcurrent protection.

Best replacement path

First, try to source the original part. If unavailable, evaluate parametric alternatives like SMD0805-020C-33V, ensuring the circuit can tolerate the higher 200mA hold current.

Main risk

The primary risk is using a substitute with a higher hold current (e.g., 200mA vs 100mA), which may fail to protect the downstream circuit from overcurrent conditions.

Recommended alternatives

2
BSMD0805-020-33V package
Needs validationmedium risk

A 0805 PTC fuse with same voltage but higher hold and trip currents. Requires engineering review.

View details

Alternative comparison matrix

Feature / factorSMD0805-010-33VBSMD0805-020-33VSMD0805-020C-33VAlt 3Compatibility / risk
Package0805080508050805 — Same 2-pin 0805 package.; SMD0805-020C-33V: Same 2-pin 0805 package.
Voltage33V33V33V33V — Maximum voltage rating matches.; SMD0805-020C-33V: Maximum voltage rating matches.
Current0.3A0.5A0.5A0.5A — Trip current is higher.; SMD0805-020C-33V: Trip current is higher.
Resistance1.0Ω0.5Ω0.5Ω0.5Ω — Initial resistance is lower.; SMD0805-020C-33V: Initial resistance is lower.

Application & sourcing insights

Questions & answers

No perfect drop-in is identified. Candidates like BNstar SMD0805-020C-33V match the package and voltage but have a higher 200mA hold current, requiring circuit analysis before use.