Package: 2920TECHFUSEPTC Resettable FusesOperating Voltage (Max): 24VHold Current: 2ATrip Current: 4ACurrent Rating (Max): 100APower Dissipation (Typ): 1.5W

Reviewing alternatives for the TECHFUSE SMD200L-24V, a 2A/24V PTC resettable fuse in a 2920 package. Key considerations for replacement are matching the 2A hold current and ensuring the maximum fault current rating is sufficient for the application.

AI replacement insight

Electrical riskmedium

Candidates have lower max fault current (40A vs 100A), which may be insufficient.

Package risklow

All viable candidates share the same 2920 package.

Can it be replaced directly?

No perfect drop-in replacement was found. The closest candidates have a lower maximum fault current rating, which requires engineering validation.

Best replacement path

BNstar SMD2920-200C-33V or BHFUSE BSMD2920-200-48V if the application's max fault current is below 40A.

Main risk

A candidate with a lower maximum fault current (Imax) could fail permanently in a high-energy fault event.

Recommended alternatives

3
SMD2920-200C-33V package
Needs validationmedium risk

Strong functional match with same hold current and higher voltage, but a lower max fault current rating.

View details

Alternative comparison matrix

Feature / factorSMD200L-24VSMD2920-200C-33VBSMD2920-200-48VSMD250L-30VCompatibility / risk
Package29202920292029202920 — Package matches.; BSMD2920-200-48V: Package matches.; SMD250L-30V: Package matches.
Current100A40A40A5.0A40A / 5.0A — Max fault current is lower, requires review.; BSMD2920-200-48V: Max fault current is lower, requires review.; SMD250L-30V: Higher trip current alters protection curve.
Voltage24V33V48V30V33V / 48V / 30V — Higher voltage rating provides more margin.; BSMD2920-200-48V: Significantly higher voltage rating.; SMD250L-30V: Higher voltage rating provides more margin.

Application & sourcing insights

Questions & answers

BNstar SMD2920-200C-33V and BHFUSE BSMD2920-200-48V are strong functional matches with the same hold/trip currents and a higher voltage rating. However, their max fault current is lower (40A vs 100A) and must be verified for your application.