Leiditech
A 4-channel ultra-low capacitance TVS array in the same SOT-363 package, but offers weaker protection levels.
TPD4E1B06DCKR-TP is a 4-channel bi-directional TVS diode array with ultra-low 0.6pF capacitance for protecting high-speed data lines. Finding a replacement requires matching the package, channel count, and especially the low capacitance and bi-directional configuration.
Higher clamping voltage and lower ESD ratings in candidates reduce protection.
SOT-363 package and 4-line pinout are common.
No direct drop-in replacement was found. All viable candidates are parametric alternatives that require careful review of protection levels.
NUP4202W1T2G-MS is the most promising path due to its very low capacitance, but requires accepting weaker clamping and ESD performance.
The primary risk is reduced system robustness due to weaker protection characteristics, specifically higher clamping voltage and lower ESD ratings in all found alternatives.

Leiditech
A 4-channel ultra-low capacitance TVS array in the same SOT-363 package, but offers weaker protection levels.
| Feature / factor | TPD4E1B06DCKR-TP | NUP4202W1T2G-MS | LC0504F | Alt 3 | Compatibility / risk |
|---|---|---|---|---|---|
| Package | SOT-363 | SOT-363 | SOT-363 | SOT-363 — Package matches.; LC0504F: Package matches. | |
| Capacitance | 0.6 pF | 0.3 pF | 0.8 pF | 0.3 pF / 0.8 pF — Lower capacitance is an improvement for high-speed signals.; LC0504F: Very close match, suitable for high-speed lines. | |
| Clamping Voltage | 9 V | 12 V | 15 V | 12 V / 15 V — Higher clamping voltage offers less protection.; LC0504F: Significantly higher Vc offers less protection. | |
| Esd Rating | ±15kV contact | ±12kV contact | ±8kV contact | ±12kV contact / ±8kV contact — Lower ESD immunity.; LC0504F: Lower ESD immunity. | |
| Voltage | 5.5 V | 5 V | 5 V | 5 V — Lower operating voltage.; LC0504F: Lower operating voltage. |
NUP4202W1T2G-MS is a potential alternative with even lower capacitance, but it has a higher clamping voltage and lower ESD rating, which reduces overall protection. Careful engineering review is required.