4532-601-LF AI Analysis:
Datasheet, Specs, Alternatives & ECAD

AI summary

4532-601-LF product

4532-601-LF

Gas Discharge Tube Arresters (GDT)

GDTSurge ProtectionSMD

The 4532-601-LF is a 600V 2-pole surface-mount Gas Discharge Tube (GDT) designed for high-surge protection in telecommunications and data lines.

Best for

  • Telecommunication interfaces
  • Modems
  • Line cards

Avoid if

  • Applications requiring extremely low clamping voltages below 400V

Check before use

  • Ensure the 1200V maximum impulse spark-over voltage is safe for downstream components.

Key specifications

DC Spark-over Voltage
420~780 V
Surge Current
2000 A
Capacitance
≤0.5 pF

Compliance & Environment

RoHS
ROHS3 Compliant
REACH
nan
MSL
1 (Unlimited)
ECCN
EAR99
HTSUS
8536.30.8000

Application

ConnectivityGeneral

Datasheet

CAD Models

Download ECAD models for 4532-601-LF: KiCad symbol & footprint, Altium footprint, PCB footprint, and 3D model.

EDA Symbol
Schematic symbol for your EDA tool
Get Files
PCB Footprint
Land pattern for PCB layout
Get Files
3D Model
STEP file for mechanical design
Get Files
KiCad Library
Verified KiCad 8 symbol, footprint, and 3D model
Generate library

Where to Buy

Real-time and catalog pricing from verified distributors

Alternative components

Alternatives are being enriched. Analyze this part in PartGenie for the latest matches.

Design and risk insights

Questions & answers

It is a surface-mount gas discharge tube (GDT) used for protecting sensitive electronic equipment from voltage surges.