F18 AI Analysis:
Datasheet, Specs, Alternatives & ECAD

AI summary

F18 product

F18

Thermal Cutoffs (Thermal Fuses)

Thermal FuseSafetyRadial

The F18 is a radial-leaded alloy thermal-link (ATCO) designed for reliable over-temperature protection in various consumer and industrial appliances.

Best for

  • Thermal protection in heating appliances
  • Transformer and motor safety

Avoid if

  • Applications requiring resettable protection
  • Environments with extreme vibration

Check before use

  • Ensure the ambient temperature does not exceed the holding temperature of 61 °C.

Key specifications

Rated Functioning Temp
86 °C
Rated Current
1 A / 3 A
Holding Temp
61 °C
Max Temp Limit
200 °C

Compliance & Environment

RoHS
RoHS Compliant
REACH
Compliant
MSL
1 (Unlimited)
ECCN
EAR99
HTSUS
9002.19.0000

Application

Consumer AppliancesIndustrial Heating

CAD Models

Download ECAD models for F18: KiCad symbol & footprint, Altium footprint, PCB footprint, and 3D model.

EDA Symbol
Schematic symbol for your EDA tool
Get Files
PCB Footprint
Land pattern for PCB layout
Get Files
3D Model
STEP file for mechanical design
Get Files
KiCad Library
Verified KiCad 8 symbol, footprint, and 3D model
Generate library

Alternative components

Alternatives are being enriched. Analyze this part in PartGenie for the latest matches.

Design and risk insights

Questions & answers

The F18 is a radial-type alloy thermal-link (ATCO) that acts as a one-time, non-resettable safety device to open a circuit when the temperature exceeds its rated functioning temperature of 86 °C.