INA300AIDGSR AI Analysis:
Datasheet, Specs, Alternatives & ECAD

AI summary

INA300AIDGSR product

INA300AIDGSR

Power Management (PMIC)

current-sense comparatorovercurrent protection36 V common modeopen-drain alertVSSOP-10

INA300AIDGSR is a 36 V common-mode current-sense comparator for fast shunt-based overcurrent detection with configurable delay, hysteresis, and open-drain alert output.

Best for

  • Fast shunt-based overcurrent protection
  • Power supply and battery charger monitoring
  • 36 V common-mode current monitoring

Avoid if

  • Bidirectional current detection is needed from one IC
  • A push-pull alert output is required
  • Continuous monitoring is not needed and enable recovery time is unacceptable

Check before use

  • Set RLIMIT using the internal 20 µA threshold current source
  • Use a pull-up resistor on ALERT
  • Route IN+ and IN- as short Kelvin connections to the shunt
  • Verify the VSSOP footprint and 0.5 mm pin pitch

Key specifications

Common-mode input range
0 V to 36 V
Supply voltage
2.7 V to 5.5 V
Differential input range
0 mV to 250 mV
Response delay
10 µs, 50 µs, or 100 µs
Package
10-pin VSSOP (DGS)

Compliance & Environment

RoHS
ROHS3 Compliant
REACH
-
MSL
Level-1-260C-UNLIM
ECCN
-
HTSUS
-

Application

Overcurrent protectionPower suppliesBattery chargersIndustrial and telecom equipment

CAD Models

Download ECAD models for INA300AIDGSR: KiCad symbol & footprint, Altium footprint, PCB footprint, and 3D model.

EDA Symbol
Schematic symbol for your EDA tool
Get Files
PCB Footprint
Land pattern for PCB layout
Get Files
3D Model
STEP file for mechanical design
Get Files
KiCad Library
Verified KiCad 8 symbol, footprint, and 3D model
Generate library

Where to Buy

Real-time and catalog pricing from verified distributors

Alternative components

Alternatives are being enriched. Analyze this part in PartGenie for the latest matches.

Design and risk insights

Questions & answers

INA300AIDGSR is a Texas Instruments INA300 overcurrent protection comparator. It measures the differential voltage across a shunt resistor and pulls its active-low open-drain ALERT output low when the programmed limit is exceeded.