ISO1050DWR product

ISO1050DWR

Drivers

Isolated CANTransceiverIndustrial5kV Isolation

The ISO1050DWR is a robust, galvanically isolated CAN transceiver ideal for industrial and automotive applications requiring high noise immunity and bus protection.

Best for

  • Industrial CAN networks
  • Isolated communication interfaces
  • Harsh electrical environments

Avoid if

  • Applications requiring CAN FD speeds (use ISO1042 instead)
  • Designs where space is extremely limited (consider smaller packages)

Check before use

  • Isolation voltage requirements
  • Secondary side power supply isolation

Key specifications

Isolation
5000 VRMS
Data Rate
1 Mbps
Bus Protection
-27V to 40V
Temp Range
-55°C to 105°C

Compliance & Environment

RoHS
ROHS3 Compliant
REACH
-
MSL
Level-2-260C-1 YEAR
ECCN
-
HTSUS
-

Application

Industrial AutomationTransportationMedical

CAD Models

Download ECAD models for ISO1050DWR: KiCad symbol & footprint, Altium footprint, PCB footprint, and 3D model.

EDA Symbol
Schematic symbol for your EDA tool
Get Files
PCB Footprint
Land pattern for PCB layout
Get Files
3D Model
STEP file for mechanical design
Get Files
KiCad Library
Verified KiCad 8 symbol, footprint, and 3D model
Generate library

Where to Buy

Real-time and catalog pricing from verified distributors

Alternative components

Alternatives are being enriched. Analyze this part in PartGenie for the latest matches.

Design and risk insights

Questions & answers

The ISO1050DWR is a galvanically isolated CAN transceiver that meets ISO11898-2 standards, providing 5000 VRMS isolation between the CAN bus and the controller.