It is a Komatsulite C-Type thermal breaker designed to protect lithium polymer and prismatic battery cells from overtemperature and overcurrent.
NR72CB0 AI Analysis:
Datasheet, Specs, Alternatives & ECAD
AI summary
Key specifications
- Trip Temperature
- 72 °C ± 5 °C
- Contact Rating
- 12 A / 12 VDC
- Max Breaking Current
- 30 A / 5 VDC
Compliance & Environment
- RoHS
- ROHS3 Compliant
- REACH
- -
- MSL
- -
- ECCN
- EAR99
- HTSUS
- 8544429090.0
Application
Battery Protection
Datasheet
CAD Models
Download ECAD models for NR72CB0: KiCad symbol & footprint, Altium footprint, PCB footprint, and 3D model.
EDA Symbol
Schematic symbol for your EDA tool
PCB Footprint
Land pattern for PCB layout
3D Model
STEP file for mechanical design
KiCad Library
Verified KiCad 8 symbol, footprint, and 3D model
Where to Buy
Real-time and catalog pricing from verified distributors
Alternative components
Alternatives are being enriched. Analyze this part in PartGenie for the latest matches.