RSCM9070-152 AI Analysis:
Datasheet, Specs, Alternatives & ECAD

AI summary

RSCM9070-152 product

RSCM9070-152

Chokes

common mode chokeSMDEMI filter3 A100 MHz

RSCM9070-152 is a four-terminal SMD common mode choke specified for 1.2 kΩ minimum impedance at 100 MHz and 3 A rated current.

Best for

  • Common-mode noise filtering
  • EMI suppression on high-frequency signal or power paths

Avoid if

  • The application requires an independently verified compliance or lifecycle status
  • The required current or thermal conditions exceed the datasheet limits

Check before use

  • PCB footprint and terminal assignment
  • Temperature rise at the intended current
  • Impedance across the operating frequency range

Key specifications

Impedance at 100 MHz
1200 Ω min.; 1500 Ω typ.
Rated current
3 A
DCR
30 mΩ max.
Dimensions
9.0 mm × 7.0 mm × 5.3 mm max.

Compliance & Environment

RoHS
-
REACH
-
MSL
-
ECCN
-
HTSUS
-

Application

Common-mode EMI filteringNoise suppression

CAD Models

Download ECAD models for RSCM9070-152: KiCad symbol & footprint, Altium footprint, PCB footprint, and 3D model.

EDA Symbol
Schematic symbol for your EDA tool
Get Files
PCB Footprint
Land pattern for PCB layout
Get Files
3D Model
STEP file for mechanical design
Get Files
KiCad Library
Verified KiCad 8 symbol, footprint, and 3D model
Generate library

Alternative components

Alternatives are being enriched. Analyze this part in PartGenie for the latest matches.

Design and risk insights

Questions & answers