SDP816-500PA AI Analysis:
Datasheet, Specs, Alternatives & ECAD

AI summary

SDP816-500PA product

SDP816-500PA

Pressure Sensors

Differential pressure sensorAnalog outputTube connection±500 PaSensirion SDP800

SDP816-500Pa is a tube-connected analog differential-pressure sensor for air and non-aggressive, non-condensing gases. It supports a ±500 Pa bidirectional square-root range or a -50 Pa to 500 Pa linear range.

Best for

  • Low-pressure air or gas differential measurement
  • Tube-connected pneumatic systems
  • Analog-input control systems

Avoid if

  • Reflow soldering is required
  • The measured medium is aggressive, condensing, or outside the stated compatibility
  • A fully bidirectional linear transfer function is required

Check before use

  • Tie OCS to GND for linear output or VDD for square-root output
  • Use the applicable pressure conversion formula for the selected range
  • Verify analog output load and input filtering requirements

Key specifications

Square-root pressure range
-500 Pa to 500 Pa
Linear pressure range
-50 Pa to 500 Pa
Supply voltage
2.7 V to 5.5 V
Response time
< 5 ms (τ63)
Output
10% to 90% of VDD ratiometric analog voltage

Compliance & Environment

RoHS
ROHS3 Compliant
REACH
REACH compliant
MSL
-
ECCN
-
HTSUS
-

Application

Airflow and pressure monitoringHVAC and industrial controls

CAD Models

Download ECAD models for SDP816-500PA: KiCad symbol & footprint, Altium footprint, PCB footprint, and 3D model.

EDA Symbol
Schematic symbol for your EDA tool
Get Files
PCB Footprint
Land pattern for PCB layout
Get Files
3D Model
STEP file for mechanical design
Get Files
KiCad Library
Verified KiCad 8 symbol, footprint, and 3D model
Generate library

Where to Buy

Real-time and catalog pricing from verified distributors

Alternative components

Alternatives are being enriched. Analyze this part in PartGenie for the latest matches.

Design and risk insights

Questions & answers

SDP816-500Pa is a Sensirion SDP800-series differential pressure sensor with tube connections and a ratiometric analog voltage output. It is calibrated and temperature compensated for air and N2.