Pricing

SF362T-LC2 AI Analysis:
Datasheet, Specs, Alternatives & ECAD

AI summary

SF362T-LC2 product

SF362T-LC2

Gas Discharge Tube Arresters (GDT)

GDTgas discharge tube3600 V3 kAaxial leadedsurge protection

SF362T-LC2 is a SET axial ceramic GDT associated with the SF362T-L series specification: 3.6 kV DC sparkover, 3 kA nominal 8/20 µs surge current, and low capacitance of ≤1.0 pF.

Best for

  • High-voltage transient diversion to ground
  • AC N-PE protection stages
  • Telecom, RF, and power-system surge protection

Avoid if

  • The circuit cannot tolerate high initial impulse sparkover voltage
  • Sustained fault-current interruption is required without external coordination

Check before use

  • Confirm exact LC2 suffix configuration with SET or the distributor
  • Verify 3.6 kV nominal DC sparkover is suitable for the protected line
  • Coordinate GDT behavior with MOVs, fuses, and downstream protection

Key specifications

SE

Manufacturer

SETsafe | SETfuse
DC sparkover voltage
3600 V @ 100 V/s
Impulse sparkover voltage
≤ 5000 V @ 1 kV/µs
Nominal discharge current
3 kA, 8/20 µs
Capacitance
≤ 1.0 pF @ 0.5 VDC, 1 MHz

Compliance & Environment

RoHS
Compliant
REACH
Compliant
MSL
-
ECCN
-
HTSUS
-

Application

AC power surge protectionTelecom and router line protectionIndustrial surge-protection assemblies

CAD Models

Generate a KiCad symbol, footprint, and 3D model for SF362T-LC2.

Loading CAD preview

Alternative components

Alternatives are being enriched. Analyze this part in PartGenie for the latest matches.

Design and risk insights

Questions & answers

SF362T-LC2 is a SET gas discharge tube arrester. The supplied SF series datasheet associates the SF362T-L version with a 3600 V DC sparkover voltage, axial leads, and a ceramic body measuring approximately Ø5.5 mm × 6.0 mm.