Pricing

TB091M-L AI Analysis:
Datasheet, Specs, Alternatives & ECAD

AI summary

TB091M-L product

TB091M-L

Ceramic Capacitors

GDT90 V10 kALeadedSurge protectionUL497B

TB091M-L is a leaded 90 V gas discharge tube for surge diversion in signal, RF, and power protection circuits. It is rated for 10 kA nominal 8/20 us surge current.

Best for

  • Surge diversion in broadband and xDSL equipment
  • Cable, satellite, RF, and base-station protection
  • Coordinated signal or power protection circuits

Avoid if

  • The normal operating voltage can exceed 72 V
  • The application can sustain excessive follow current without coordination

Check before use

  • Verify operating voltage against the minimum breakdown voltage
  • Validate surge coordination and follow-current interruption
  • Confirm footprint and lead spacing

Key specifications

SE

Manufacturer

SETsafe | SETfuse
DC breakdown voltage
90 V at 100 V/s
Impulse breakdown voltage
<=600 V at 1 kV/us
Nominal discharge current
10 kA, 8/20 us
Arc voltage
approximately 8 V at 1 A
Capacitance
<=1.0 pF at 1 MHz

Compliance & Environment

RoHS
Compliant
REACH
Compliant
MSL
-
ECCN
-
HTSUS
-

Application

Broadband and xDSL protectionCable, satellite, and RF equipmentPower surge protection

CAD Models

Generate a KiCad symbol, footprint, and 3D model for TB091M-L.

Loading CAD preview

Alternative components

Alternatives are being enriched. Analyze this part in PartGenie for the latest matches.

Design and risk insights

Questions & answers

TB091M-L is a SET leaded gas discharge tube (GDT) with a 90 V DC breakdown voltage at 100 V/s.