It is a Bourns dual unidirectional TBU transient blocking unit in a DFN package. It is placed in series with two signal lines and provides resettable protection against excessive fault and surge current.
TBU-DT065-200-WH AI Analysis:
Datasheet, Specs, Alternatives & ECAD
AI summary
Key specifications
BO

Manufacturer
BOURNS- Trigger current
- 200 mA min.; 300 mA typ.; 400 mA max.
- Impulse withstand
- 650 V for less than 10 ms
- Continuous AC voltage
- 300 VAC RMS
- Blocking time
- 1 µs max.
- Series resistance
- 5.6 Ω typ.; 6.6 Ω max.
- Package
- 5.00 mm × 5.00 mm DFN
Compliance & Environment
- RoHS
- ROHS3 Compliant
Application
Ethernet port protectionIndustrial process-control interfacesTest and measurement equipmentGeneral signal-line protection