TPSMD4532-075NF AI Analysis:
Datasheet, Specs, Alternatives & ECAD

AI summary

TPSMD4532-075NF product

TPSMD4532-075NF

Ceramic Capacitors

GDTsurge protection75 V45321812low capacitancetelecom protection

TPSMD4532-075NF is a 75 V surface-mount gas discharge tube intended for low-capacitance surge protection on communications and data interfaces.

Best for

  • Telecom line surge protection
  • Low-capacitance data-line protection
  • CATV and broadband equipment

Avoid if

  • Direct operation in power-supply networks
  • Circuits that cannot tolerate the stated spark-over-voltage tolerance

Check before use

  • 75 V ±30% DC spark-over voltage
  • 600 V maximum impulse spark-over voltage at 1 kV/µs
  • 2.0 kA 8/20 µs nominal impulse discharge-current rating
  • 4.5 mm × 3.2 mm × 2.7 mm nominal package dimensions

Key specifications

DC spark-over voltage
75 V ±30% at 100 V/s
Impulse spark-over voltage
600 V maximum at 1 kV/µs
Impulse discharge current
2.0 kA at 8/20 µs, ±5 times
Impulse withstand voltage
4 kV at 10/700 µs, ±5 times
Capacitance
≤0.6 pF at 1 MHz

Compliance & Environment

RoHS
-
REACH
-
MSL
MSL 1
ECCN
-
HTSUS
-

Application

Telecom and SLIC protectionData-line surge protectionCATV and broadband equipment

CAD Models

Download ECAD models for TPSMD4532-075NF: KiCad symbol & footprint, Altium footprint, PCB footprint, and 3D model.

EDA Symbol
Schematic symbol for your EDA tool
Get Files
PCB Footprint
Land pattern for PCB layout
Get Files
3D Model
STEP file for mechanical design
Get Files
KiCad Library
Verified KiCad 8 symbol, footprint, and 3D model
Generate library

Alternative components

Alternatives are being enriched. Analyze this part in PartGenie for the latest matches.

Design and risk insights

Questions & answers

TPSMD4532-075NF is a TECH PUBLIC surface-mount gas discharge tube (GDT) surge-protection component in a 4532 (1812) package. Its nominal DC spark-over voltage is 75 V ±30%.