V39ZA1P AI Analysis:
Datasheet, Specs, Alternatives & ECAD

AI summary

V39ZA1P product

V39ZA1P

MOVs

MOVvaristorradial lead7 mm disc25 VAC31 VDCsurge protection

V39ZA1P is a 7 mm Littelfuse radial MOV for transient suppression on circuits up to 25 VAC or 31 VDC. It provides 79 V maximum clamping at 2.5 A and a 250 A 8/20 µs surge-current rating.

Best for

  • Transient suppression on 25 VAC or 31 VDC circuits
  • Motor-control, telecom, solenoid, and power-supply protection

Avoid if

  • The protected circuit cannot tolerate up to 79 V clamping at the specified test current
  • Surge energy or repetitive pulse loading exceeds the qualified rating curves
  • Continuous voltage exceeds 25 VAC RMS or 31 VDC

Check before use

  • Validate clamping voltage at the actual surge current
  • Apply temperature derating above 85 °C ambient
  • Check MOV degradation and end-of-life protection strategy

Key specifications

Continuous voltage
25 VAC RMS / 31 VDC
Varistor voltage
35.1 V to 42.9 V at 1 mA
Maximum clamping voltage
79 V at 2.5 A, 8/20 µs
Peak pulse current
250 A, 8/20 µs
Energy rating
1.2 J, 10/1000 µs
Disc diameter
7 mm

Compliance & Environment

RoHS
ROHS3 Compliant
REACH
-
MSL
-
ECCN
-
HTSUS
-

Application

Motor-control transient protectionPower-supply surge suppressionTelecom and solenoid circuits

Datasheet

CAD Models

Download ECAD models for V39ZA1P: KiCad symbol & footprint, Altium footprint, PCB footprint, and 3D model.

EDA Symbol
Schematic symbol for your EDA tool
Get Files
PCB Footprint
Land pattern for PCB layout
Get Files
3D Model
STEP file for mechanical design
Get Files
KiCad Library
Verified KiCad 8 symbol, footprint, and 3D model
Generate library

Where to Buy

Real-time and catalog pricing from verified distributors

Alternative components

Alternatives are being enriched. Analyze this part in PartGenie for the latest matches.

Design and risk insights

Questions & answers

V39ZA1P is a Littelfuse ZA Series radial-leaded metal-oxide varistor (MOV) with a 7 mm disc. It is intended to clamp transient overvoltage events in low- and medium-voltage circuits.